SUNTEST XXL+ FD

Light stability testing of Consumer Goods and Packaging

SKU: c63e5833b36f Categories: , ,

Description

The Atlas SUNTEST XXL+FD is an extra-large light stability test chamber especially tailored towards the needs of consumer goods, food and beverage testing. Its 3000 cm2 flatbed exposure area and tall chamber height is best-in-class for 3-D specimens testing and can accommodate all types of bottles and packaging.

The SUNTEST XXL+FD is used to determine the light stability of new ingredients, products or packaging for food, beverages, or other FMCG (fast moving consumer goods) applications. It’s also extremely useful to perform highly accelerated shelf-life tests (ASLT) within days. A powerful chiller guarantees light stability testing under realistic temperature conditions, for example on the retail shelf or during indoor/outdoor storage and use.

Benefits:

  • Premium simulation of outdoor/indoor sunlight
  • Simulation of artificial supermarket light
  • Best-in-class chamber design for testing large 3-D specimens
  • Powerful chiller for ideal test temperature conditions, even at high irradiance
  • Easy-to-use touch screen user interface with 13 selectable languages
  • Access port for additional external sensors
  • Automatic control of irradiance for various testing needs
  • Dimensions 90 x 91 x 172 cm
  • 39 x 72 cm (3000 cm2) exposure area
  • 3 air-cooled 1700 W xenon lamps
  • Easy-to-use touch screen user interface with 13 selectable languages
  • Direct setting and control of irradiance at 300-400 nm, 340 nm
  • Direct setting and control of Black Standard Temperature (BST) or Black Panel Temperature (BPT)
  • Direct setting and control of chamber temperature (CHT)
  • Direct setting of tolerance ranges for each test parameter for optimum test control
  • Display of diagnostic messages
  • 10 free programmable tests possible with up to 12 phases
  • Pre-programmed polymer and coatings standards for Quick-starters
  • Horizontal 3000 cm² exposure area for 34 standard or multiple 3-D specimens
  • Premium sunlight simulation according to CIE85 reference sun
  • Lamp cassette with aluminum reflector, lamp connections and filter slot
  • Outer filter with IR-reflective coating
  • Irradiance range 30-65 W/m2 (300-400 nm); 0.26-0.62 W/m2 (340 nm)
  • SunCool for SUNTEST XXL+ for testing at low chamber temperatures (15-30°C); detachable for standard weathering testing needs (CHT up to 70°C)
  • Measurement and control of BST or BPT: 25°C – 100 ºC (with SunCool)
  • BST sensor design according to ISO 4892-1
  • Thermal insulation of test chamber and peripheral parts preventing condensation
  • Selectable temperature control either by CHT or by dual control: CHT and BST (BPT) simultaneously
  • Controlled temperature difference between CHT and BST / (BPT)
  • Ultrasonic humidification system for humidity control (operation without SunCool)
  • Specimen spray system with integrated 60 l water reservoir for spray cycles at 25°C – 70°C (with SunCool)
  • 5° tilted specimen test plane for spray water draining
  • Access port ca. 30 x 25 mm to connect external sensors inside the test chamber
  • Switch-off by radiant exposure, light exposure time or total operating time
  • Advanced auto-start functions
  • Data output via memory card or RS 232
  • Internal memory chip for storing instrument data
  • Ethernet interface for network connections. See optional XenoTouch Software Add-ons 1, 2, and 3 (“Remote Control“, “E-Mail Service“, “Online Monitoring“)
  • Light Monitor 420 nm
  • BST/BPT exchange kit
  • Daylight filter
  • Window Glass filter
  • Solar ID 65 filter
  • BPT sensor
  • Specimen holders and masks
  • ICH-D10/20/30 powder sample holders for preparation of 1-3 mm powder samples (Pharmaceuticals)
  • Sliding sample table with exposure area of 740 x 368 mm
  • Air outlet hood for connecting the 3 outlets to a laboratory ventilation system
  • SunCal BB 300-400 BST sensor for calibration of irradiance in W/m² in the wavelength range 300-400 nm and for calibration of BST in °C

The listed standards and specifications may include several alternative testing options. The instrument meets at least one option in any listed standard. Standards are subject to change without notification, which may result in a change in testing technology. Always check the revision status of a standard with the responsible Standards Development Organization. If unsure about instrument compliance, please contact your local sales representative.

  • ICH Q1B
    Q1B Photostability Testing of New Drug Substances and Products
  • ICH Q5C
    Stability testing of Biotechnological / Biological products
  • VICH GL5
    Guideline On Stability Testing: Photostability Testing of New Veterinary Drug Substances and Medicinal Products